1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 347Get this manual

1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 347

Starter Circuit Check Chart I Note Battery must be fully charged

Procedure Remove black lead from ground at CD Connect voltmeter between CD and common engine groundTurn key to START positionVoltmeter should show battery voltageConnect meter at Turn key to START position
Result aIf no reading, go to Step

Check voltage between ground Steps thru Remove starter to solenoid cable from (j) to prevent starter engagement while making checksbetween ground

bIf meter reads battery voltage, reconnect black lead to ground and go to Step

II Check voltage
INotel Steps thru Turn key OFF before connecting and disconnecting meterTurn key to START position after connecting

aIf meter reads battery voltage, lead is open between CD and

bIf no reading, go to Step