Ohmmeter TestStop Circuit Note All ohmmeter tests must be performed with the engine not running
[II [II [II [II

1Attach clip and lanyard to emergency stop switch 2Separate the 2-pin Amphenol connector 3Separate he 1-pin Amphenol connector

between power pack and key switch
between engine wiring harness and shift switch
4Calibrate ohmmeter on appropriate scale5Connect meter black lead to clean engine groundConnect meter red lead to connector terminal "8" (blackyellow) wire Key OFF, meter must show low resistance Key ON, meter must show high resistance6If Step key ON reading is low one, disconnect harness blackyellow lead from key switch "M" terminal If meter now shows high reading, replace key switch If meter shows low reading, go to Step 7