1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 163Get this manual

1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 163

4 DRC6144

DRC6145

Ohmmeter TestStop Circuit

rn rn rn rn

All ohmmeter tests must be performed with the engine not running
1Attach clip and lanyard to emergency stop switch2Separate the 2-pin Amphenol connector

between power pack and key switch
3Separate the 1-pin Amphenol connector between engine wiring harness and shift switch
4Calibrate ohmmeter on appropriate scale
5Connect meter black lead to clean engine groundConnect meter red lead to connector terminal "8" (blackyellow) wire Key OFF, meter must show low resistance Key ON, meter must show high resistancem