1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 157Get this manual
Ohmmeter Test
All ohmmeter tests must be performed with engine not running
1Calibrate ohmmeter on appropriate scale
2Attach ohmmeter black lead to port timer base connector, terminal "E"
3Alternately, attach ohmmeter red lead to each terminal in starboard timer base connectorObserve meter reading at each connection Meter must show 130 30 ohms
4Alternately, attach ohmmeter red lead to each terminal in port timer base connectorObserve meter reading at each connection Meter must show 45 10 ohms