1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 149Get this manual

1996 Johnson Evinrude "ED" 90 LV 125C, 130, 200, 225, 250 Service Manual, P/N 507128, Page 149

7 DR4039 DR4040

7All modelsdisconnect power coil orange and orangeblack leadsrJl 8Calibrate ohmmeter on appropriate scaleAlternately, attach meter leads between each power coil lead and engine ground Meter must show high reading
[!] 9Attach meter leads to power coil orange and orangeblack leads If meter shows 96 10 ohms, replace power pack If your test results vary, replace stator
INotel Do not run the engine with its power coil leads disconnected!
QuikStart Always ON
If QuikStart electronic starting remains on constantly when engine is operated above 1100 RPM, replace the power packIf QuikStart electronic starting disregards time and engine temperature and remains on co nstantly when engine is operated below 1100 RPM: 1Check for trace amounts of battery voltage on power pack yellowred lead indi catin damaged starter solenoid 2Check for damaged port temperature switchRefer to Temperature Switch Test, Section 43Check for open power pack whiteblack lead or damaged connectors4Check engine temperature for overcooling conditionRefer to Engine Temperature Check, Section 45Replace power packE u