RectifierRegulator Tests Variable Load Tests To test the operation of the rectifierregulator, you must be able to run the engine continuously at approximately 4500 RPM, such as in test tank, on marine dynamometer, or on the boatThe test consists of monitoring the system's response to partially discharged batteryTwo methods for performing this test are described belowVariable Load High Rate Discharge Tester

INote The

rectifierregulator requires battery voltage from the purple lead to operateBefore proceeding, verify battery voltage at terminal strip purple leads when key is ON
2Connect 0-40 amp ammeter in series between the rectifierregulator red lead and the battery side of the starter solenoid3Reconnect the engine's battery cables

1Disconnect battery cables
4Following the manufacturer's directions, connect the variable load tester (carbon pile) across the battery terminalsSteven's Instrument Model NoLB-85 and Snap-on Model NoMT540D are examples of testers availablemight overheat battery causing electrolyte gassingThis might create an explosive atmosphere