1996 Johnson Evinrude "ED" 90 CV 88 thru 115 Service Manual, P/N 507126, Page 233Get this manual

1996 Johnson Evinrude "ED" 90 CV 88 thru 115 Service Manual, P/N 507126, Page 233

Solenoid Tests

All engine wiring must be disconnected from the solenoid before proceeding with this test

1Calibrate ohmmeter on appropriate scaleConnect one lead to terminal and the other lead to terminal The ohmmeter should show high reading If the ohmmeter shows low reading, replace the solenoid

2Attach positive battery jumper to terminal and negative battery jumper to terminal The solenoid should close with an audible click The ohmmeter should show low reading If the ohmmeter shows high reading, replace the solenoid3After installing the solenoid, coat all wires and terminals, except the battery" +" connection, with OMC Black Neoprene Dip

No Load Current Draw, Electric Starter

Securely fasten starter in vise or other suitable fixture before proceeding with this check1Locate battery rated at 350 CCA (70 amphrs or higher that is in good condition and fully charged, to perform this test