Starter System Voltage Drop Test
By making systematic check of the starter system, any component or electrical connection having excessive resistance can be located

accidental starting of engine while servicing; twist and remove all spark plug leads
Clean and retighten, or replace, any connection, cable, or component having greater than specified voltage drop

1Connect voltmeter positive lead to battery positive postConnect voltmeter negative lead to starter solenoid positive terminalTurn key switch to START to crank engineVoltage reading should not exceed 0.3 voltStep 2, connect the voltmeter leads only while the engine is cranking, or damage to the voltmeter can occur