1996 Johnson Evinrude "ED" 90 CV 88 thru 115 Service Manual, P/N 507126, Page 220Get this manual

1996 Johnson Evinrude "ED" 90 CV 88 thru 115 Service Manual, P/N 507126, Page 220

Shift Cable AdjustmentRemote Control Models
i from forward boat travel could move the gate into RE-

The shift cable must be adjusted correctly or water pressure

VERSE, causing the boat to stop abruptlyOccupants could be thrown about or ejectedr:JOl1Pull up on shift cam until cam roller is at the far end of the FORWARD detent range
1111 2Shift remote control to

FORWARD positionTemporarily push cable guide onto shift cam stud Pull firmly on cable casing to remove free-playAdjust cable trunnion to align with trunnion anchor bracket Pull cable off the stud

3Insert cable trunnion in anchor bracket and turn 90 to lock the trunnion in place4Push cable guide onto studInstall washer and hand tighten the locknutr:J2l 5Shift remote control to NEUTRALThe cam roller should snap into NEUTRAL detent when you pull up on the reverse gate with moderate pressure6If you cannot achieve NEUTRAL detent, lengthen cable slightly and recheck your adjustment