1996 Johnson Evinrude "ED" 90 CV 88 thru 115 Service Manual, P/N 507126, Page 120Get this manual

1996 Johnson Evinrude "ED" 90 CV 88 thru 115 Service Manual, P/N 507126, Page 120



Ohmmeter Test INotel All ohmmeter tests must be performed with the engine not running1Calibrate ohmmeter on appropriate scale
[!3] 2Attach ohmmeter black lead to timer base connector, terminal "E"f121 3Alternately, attach ohmmeter red lead to each terminal in the timer base connectorObserve ohmmeter reading at each connection Meter must show 40 10 ohms'13l 4To test for grounded condition, connect ohmmeter, alternately, between each timer base terminal location and clean engine ground Meter must show high reading If meter shows low reading, locate and repair ground or replace timer base5Complete all circuits disconnected during this test