Cranking Discharge Method
1Check battery voltage If voltage is greater than 12.5 volts, go to Step If voltage is less than 12.5 volts, go to Step 32Twist the spark plug leads and remove them from the spark plugsCrank the engine in short bursts until battery voltage is less than 12.5 voltsCheck battery voltage with key OFF3Disconnect the battery cables4Connect 0-40 amp ammeter in series between the rectifier regulator red lead and the battery side of the starter solenoid5Reconnect the battery cables and the spark plug leads
INote The