No Load Current Draw, Electric Starter Notel Securely fasten starter in vise or other suitable fixture
before proceeding with this check1Locate battery rated at 500 CCA (60 amp-hrs) or higher that is in good condition and fully charged

2a 0-100 amp ammeter in series with heavy jumper between the battery "+" terminal and the starter "+" terminal

3Attach or hold vibration tachometer, such as Frahm Reed tachometer, to the starter4Complete the circuit with heavy jumper between the battery "_" terminal and the starter frame5Monitor the starter RPM and current draw and refer to the chart below for the correct specificationsNo Load Current Draw Specifications Amps (Maximum)