1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 237Get this manual

1996 Johnson Evinrude "ED" 60 LV 90, 115, 150, 150C, 175 Service Manual, P/N 507127, Page 237

Shift Cable Adjustment
i from forward boat travel could move the gate into RE-

"" The shift cable must be adjusted correctly or water pressure

VERSE, causing the boat to stop abruptlyOccupants could be thrown about or ejectedf1Ol 1Pull up on shift cam until cam roller is at the far end of the FORWARD detent range r:J1l 2Shift remote control to FORWARD positionTemporarily push cable guide onto shift cam stud Pull firmly on cable casing to remove free-playAdjust cable trunnion to align with trunnion anchor bracket Pull cable off the stud3Insert cable trunnion in anchor bracket and turn 90 to lock the trunnion in place4Push cable guide onto studInstall washer and hand tighten the locknutf121 5Shift remote control to NEUTRALThe cam roller should snap into NEUTRAL detent when you pull up on the reverse gate with moderate pressure6If you cannot achieve NEUTRAL detent, lengthen cable slightly and recheck your adjustmentIt is very important that the reverse gate must remain locked in the FORWARD detent range when remote control is in FORWARDWhen properly adjusted, the reverse gate cannot be pulled out of the FORWARD detent range by hand7Tighten locknut and loosen 18 to turn to permit free movement of camf131 8Loosely secure shift cable to the steering cable with tie strapDO NOT restrict movement of the shift cable