Shift Lever Detent Adjustment 1Rotate propeller shaft and move the remote control handle to NEUTRAL position2Remove shift cable trunnion nut from anchor pocket[] 3Loosen detent spring adjustment screwand remove neutral lockout link connector from shift lever 4Verify gearcase is in NEUTRAL positionMove the detent spring to fully engage notch of the shift lever detentTighten detent adjustment screw

5Move neutral lockout link to position starter lockout plunger in horizontal position6Adjust connector on the neutral lockout link to maintain starter lockout plunger in horizontal position when connector is installed on shift lever7Install neutral lockout link connector on shift lever