Starter Circuit CheckTEL, TTL i ing with this check

Avoid accidental starting while testing; disconnect the starter cable at point CD before proceed-

Notel Engine must be in NEUTRAL throughout test procedureBattery must be fully chargedStep Procedure Connect voltmeter between and groundPress start button Connect voltmeter between and groundPress start button Connect voltmeter between and groundResult

Check voltage between and ground

If meter shows 12V, test starter If meter shows OV, go to Step
fJ and groundbetween Check voltage

If meter shows 12V, test cable to starter If meter shows OV, go to Step

Check voltage between and ground

If meter shows OV, check battery cable and battery If meter shows 12V, go to Step

II Check groundbetween voltage and

Connect voltmeter between and groundTurn key switch ONPress start button Connect voltmeter between and groundTurn key switch ONConnect voltmeter between and ground

IIIf meter shows 12V, go to Step IIIf meter reads OV, go to Step II