The ignition module incorporates the S.L.OWwarning systemThis system gradually limits engine speed to approximately 2500 RPM when either the: Engine temperature exceeds 240 (1160 C), on remote control models Oil level in the oil tank drops below predetermined level Once the S.L.OWwarning system has activated, the engine must cool to allow the temperature switch to open or outboard lubricant must be added to the oil tankThe engine must be operated below 1500 RPM before normal operation can be resumedThe ignition module also incorporates QuikStart electronic starting, which automatically advances the ignition timing when the engine temperature is less than 1050 (41 C), and for approximately seconds each time the engine is started, to ensure reliable startsStop Circuit

The stop buttonkey switchand emergency stop switch are connected to the ignition module through the engine wiring harnessWhen activated, these switches direct the ignition module output to ground, stopping the ignition systemThe steering handle contains combination stop switch emergency stop device When the clip and lanyard assembly is removed, the emergency stop device is in the STOP position When the clip and lanyard assembly is installed, the emergency stop device is in the RUN position To stop the engine when the clip and lanyard assembly is in place, press the stop button inward until the engine stops