1995 Johnson Evinrude "EO" 90 CV 85 thru 115 Service Manual, P/N 503150, Page 257Get this manual

1995 Johnson Evinrude "EO" 90 CV 85 thru 115 Service Manual, P/N 503150, Page 257

6With the engine running at 1000 RPM, disconnect the tachometer and observe the voltmeterVoltage should increase approxi mately voltDisconnect the VRO pump's 4-pin Amphenol connectorVoltage should increase approximately volts If the voltmeter shows higher voltage than specified on both components, replace the rectifierregulator If the voltmeter shows higher voltage than specified on one component, replace that component rr::J=Jt

Do not energize primer solenoid when performing Steps 7, 8, and 9
f3'l 7Check for voltage at the gray terminal with the engine not running and the key switch in the "ON" position If the voltmeter does not show voltage, the tachometer circuit is okayCheck the warning horn circuitRefer to Warning Horn, Section If the voltmeter shows voltage, go to Step 8
f41 8With the engine not running and the key switch in the "ON"
position, disconnect the gray leads from the terminal boardCheck for voltage at the rectifierregulator gray lead If voltmeter does not show voltage, go to Step If voltmeter shows voltage, replace the rectifier regulator