1994 Johnson/Evinrude Outboards 40 thru 55 Service Manual, Page 275Get this manual

1994 Johnson/Evinrude Outboards 40 thru 55 Service Manual, Page 275

Starter Circuit CheckTEL, TTL i ing with this check

Avoid accidental starting while testing; disconnect the starter cable at point CD before proceed-

INote Engine must be in NEUTRAL throughout test procedureBattery must be fully chargedStep Procedure Connect voltmeter between and groundPress start button Connect voltmeter between and groundPress start button Connect voltmeter between and groundResult

Check voltage between and ground

If meter shows 12V, test starter If meter shows OV, go to Step
II and voltage between Check groundB and voltagebetween Check ground II and voltage between Check groundB and groundbetween Check voltage

If meter shows 12V, test cable to starter If meter shows OV, go to Step

If meter shows OV, check battery cable and battery If meter shows 12V, go to Step

Connect voltmeter between and groundTurn key switch ONPress start button Connect voltmeter between and groundTurn key switch ON Connect voltmeter between and ground