1994 Johnson/Evinrude "ER" CV 85 thru 115 outboards Service Manual, Page 282Get this manual

1994 Johnson/Evinrude "ER" CV 85 thru 115 outboards Service Manual, Page 282

r;;l 5Connect 12-volt source to the relay "S" terminalsUse an ohmmeter calibrated on high ohms scale or continuity light to test for continuity on relay terminals "8+" and "M" The meter must show continuity1sl 6Leave the 12-volt source connected to the "S" terminalsConnect meter leads to relay terminals "8-" and "M" The meter must show no continuity7If your results vary, replace the relayDR3950