1994 Johnson/Evinrude "ER" CV 85 thru 115 outboards Service Manual, Page 235Get this manual

1994 Johnson/Evinrude "ER" CV 85 thru 115 outboards Service Manual, Page 235

3Capacity Test Satisfactory capacity tests can be made only when the battery electrolyte equals or exceeds 1.225 specific gravity at 80F (2JDC)4Terminal Voltage Test
ill procedures could

Use extreme caution during any load testingImproper overheat battery and cause electrolyte gassingYou might create an explosive atmosphere
aVariable Load High Rate Discharge Tester (Recommended) Connect tester to battery terminal postsDischarge at rate of three times battery ampere hour rating for 15 secondsIf the voltage is 9.6 volts or higher at the end of 15 seconds, the battery has good output capacitybFixed Resistance Tester This equipment has built-in load for high-rate discharge testingFollow equipment manufacturer's instructions regarding test period and meter readingscEngine Load for Resistance Disconnect charge coil connectors between stator and power packConnect voltmeter across the batteryCrank engine for 15 secondsIf voltage is 9.6 volts or higher at the end of 15 seconds, the battery has good output capacity