1994 Johnson/Evinrude "ER" 9.9 thru 30 outboards Service Manual, Page 299Get this manual

1994 Johnson/Evinrude "ER" 9.9 thru 30 outboards Service Manual, Page 299


Starter System Voltage Drop Test
By making systematic check of the starter system, any component or electrical connection having excessive resistance can be located
i and remove all spark plug leads
"" Avoid accidental starting of engine while servicing; twist

Clean and retighten, or replace, any connection, cable, or component having greater than specified voltage drop
r;;J 1Connect voltmeter positive lead to battery positive postConnect voltmeter negative lead to starter solenoid positive terminalTurn key switch to START to crank engineVoltage reading should not exceed 0.3 voltIn Step 2, connect the voltmeter leads only while the engine is cranking, or damage to the voltmeter can occurrJl2Connect voltmeter negative lead to the starter side of the starter solenoid terminalWhile cranking engine, connect voltmeter positive lead to starter solenoid opposite terminalVoltage reading should not exceed 0.2 voltRemove voltmeter positive lead from starter solenoid and stop cranking engine