1994 Johnson/Evinrude "ER" 60 thru 70 outboards Service Manual, Page 256Get this manual

1994 Johnson/Evinrude "ER" 60 thru 70 outboards Service Manual, Page 256

6With the engine running at 1000 RPM, disconnect the tachometer and observe the voltmeterVoltage should increase approximately voltDisconnect the VRO pump's 4-pin Amphenol connectorVoltage should increase approximately volts If the voltmeter shows higher voltage than specified on both components, replace the rectifierregulator If the voltmeter shows higher voltage than specified on one component, replace that component rJ N

Do not energize primer solenoid when performing Steps 7, 8, and 9
rJ17Check for voltage at the gray terminal with the engine not running and the key switch in the "ON" position If the voltmeter does not show voltage, the tachometer circuit is okayCheck the warning horn circuitRefer to Warning Horn, Section If the voltmeter shows voltage, go to Step 8Q 8With the engine not running and the key switch in the "ON" position, disconnect the gray leads from the terminal boardCheck for voltage at the rectifierregulator gray lead