Stator Resistance CheckAll Models
Disconnect battery cables before proceeding with this check
f31 1Disconnect stator yellow and yellowgray leads from terminal board
r:;-J 2Calibrate ohmmeter on appropriate scaleConnect one ohmmeter lead to stator yellow lead and the other ohmmeter lead to stator yellowgray lead Refer to chart below for the correct value for your engine and stator combination Repair or replace stator if reading is not correctf41 3To check for grounded condition, disconnect both ohm meter leadsCalibrate ohmmeter on appropriate scaleConnect one ohmmeter lead to clean engine ground and the other ohmmeter lead alternately to both stator leads Ohmmeter should show high reading If ohmmeter shows low reading, stator is grounded and should be repaired or replacedAfter replacing the stator and charge coil assembly, verify correct maximum spark advance using the procedure outlined in Section 1