1994 Johnson Evinrude "ER" 60 LV 150, 150C, 175 Service Manual, P/N 500611, Page 277Get this manual

1994 Johnson Evinrude "ER" 60 LV 150, 150C, 175 Service Manual, P/N 500611, Page 277

7(continued) If no voltage at V3disconnect bluewhite tilt limit switch bullet connectors and re-connect to by-pass tilt limit switchRepeat Step 7If you now have voltage at V3adjust or replace tilt limit switch If voltage at V3go to Step 88Reinstall UP relayPush blades only halfway into bracket in UP (blue) end of bracket [!]

9Push UP trim button and check for voltage at V4 on relay blade (M terminal of relay) If no voltage at V4go to Relay Ohmmeter Test If voltage at V4go to Step 10
10Disconnect trim motor's blue and green power wire connector (leave relay in bracket)11Push UP trim buttonCheck for voltage on blue wire If no voltage on blue wire, check blue wire from relay bracket to motor connector If voltage on blue wire, check motor and leadDOWN CIRCUIT 12Mark UP and DOWN relays, and remove relays from relay bracket