1994 Johnson Evinrude "ER" 60 LV 150, 150C, 175 Service Manual, P/N 500611, Page 254Get this manual

1994 Johnson Evinrude "ER" 60 LV 150, 150C, 175 Service Manual, P/N 500611, Page 254

Cranking Discharge Method
1Check battery voltage If voltage is greater than 12.5 volts, go to Step If voltage is less than 12.5 volts, go to Step 32Twist the spark plug leads and remove them from the spark plugsCrank the engine in short bursts until battery voltage is less than 12.5 voltsCheck battery voltage with key OFF3Disconnect the battery cables4Connect 0-40 amp ammeter in series between the rectifier regulator red lead and the battery side of the starter solenoid5Reconnect the battery cables and the spark plug leads
The rectifierregulator requires battery voltage from the purple lead to operateBefore proceeding, separate the rectifierregulator purple lead bullet connectorVerify battery voltage at the engine harness connector when key is ONReconnect the purple lead bullet connector
6Start the engine and run it at approximately 4500 RPMThe ammeter should indicate nearly full output35 ampsWhile continuing to run at 4500 RPM, the voltage should stabilize at about 14.5 volts and the alternator output should begin to decrease If your results vary, check the stator's condition before replacing the rectifierregulatorTachometer Circuit