1994 Johnson Evinrude "ER" 60 LV 150, 150C, 175 Service Manual, P/N 500611, Page 105Get this manual

1994 Johnson Evinrude "ER" 60 LV 150, 150C, 175 Service Manual, P/N 500611, Page 105

Principles of Operation Flywheel

f1l The flywheel contains the permanent magnets necessary to

energize the charge coils and power coilOnce the flywheel exceeds minimum cranking RPM, the flywheel's magnetic lines of force passing through the charge coil and power coil windings produce voltage in those circuits
The charge coil and power coil magnets are located around the flywheel's inner rimCharge Coils

f21 The charge coils are located on the stator assemblyThey

contain many windings (strands of wire wrapped around metal lamination)Once the flywheel exceeds minimum cranking RPM, the flywheel's magnetic lines of force cut through the coil windings to produce voltageThe voltage is supplied to the power pack to operate the ignition system
Power Coil

f21 The power coil is located on the stator assemblyIt contains

many windings (strands of wire wrapped around metal lamination) Once the flywheel exceeds minimum cranking RPM, the flywheel's magnetic lines of force cut through the coil windings to produce voltageThe voltage is supplied to the power pack to operate the following systems: