Battery Testing Battery electrolyte is acidichandle with careIf electrolyte contacts any part of the body, immediately flush with water and seek medical attentionVisual Inspection The first step in determining the condition of battery should be visual inspectionLook for conditions such as damage to the case, loose terminal, and evidence of electrolyte seepageThese signs may indicate improper care, installation, or application of the batteryLook for excessive corrosion on the battery terminals and cablesCheck the battery cables for worn or frayed insulationReplace cables, if necessaryCheck the electrolyte level in each cellIf electrolyte level is below the plates, it is possible the battery is permanently damagedAlso look for dirt, oil, or other contaminants floating in the electrolyte842018

Hydrometer Testing

INote Disconnect the positive battery cable whenever charging
the batteryThis test can only be used when there is sufficient electrolyte above the battery plates to fill the hydrometer tubeDo not, however, take readings immediately after refilling the cells with waterThe battery must be charged, then check with hydrometerView the hydrometer with your eye on the same level with the liquid surfaceThe float of the hydrometer must be freeMake correction for the temperatureSpecific gravity will vary points (0.004) with every 1QF (6C) temperature changeFor each 10F (6C) below 80F (2JDC), subtract points from hydrometer readingFor each 10F (6C) above 80F (27C), add points to hydrometer readingAfter correcting to 80F (2JDC), interpret readings as follows: All cell readings uniform and above 1.225 specific gravity indicates battery is serviceable, but may require charging All cell readings uniform and below 1.225 specific gravity, charge fully and retest Variation of more than 30 points (0.030) specific gravity between any two cells, indicates battery condition is questionableRecharge and retest before replacing battery