1993 Johnson Evinrude "ET" Electric Outboards Service Manual, P/N 508280, Page 56Get this manual

1993 Johnson Evinrude "ET" Electric Outboards Service Manual, P/N 508280, Page 56

Continuity TestNegative Circuit, Foot Control, Except HBF2
INote To avoid damaging components or troubleshooting equipment, disconnect the battery cables before proceeding1Use an ohmmeter calibrated on high ohms scale or continuity light to test continuity2Connect one meter lead to BLACK battery cableLeave this meter lead connected for all the following tests3Connect second meter lead to BLACK 14-Galead at foot pedal terminal strip: The meter must show continuity If meter shows no continuity, repair or replace battery cables

rn 4Remove the steering housing cover5Connect second meter lead to BLACK 14-Galead at steering housing terminal strip: The meter must show continuity If meter shows no continuity, repair or replace wiring harness between foot pedal and steering housing6Remove motor from adapter housingDo not disconnect the motor leads at this timeCarefully, uncover wire splice on BLACK 14-Gamotor lead