1993 Johnson Evinrude "ET" 90 degrees CV Service Manual, P/N 508285, Page 249Get this manual

1993 Johnson Evinrude "ET" 90 degrees CV Service Manual, P/N 508285, Page 249

RectifierRegulator Tests Variable Load Tests To test the operation of the rectifierregulator, you must be able to run the engine continuously at approximately 4500 RPM, such as in test tank, on marine dynamometer, or on the boatThe test consists of monitoring the system's response to partially discharged batteryTwo methods for performing this test are described belowVariable Load High Rate Discharge Tester

The rectifierregulator requires battery voltage from the purple lead to operateBefore proceedingverify battery voltage at terminal strip purple leads when key is ON1Disconnect battery cables

rl 2Connect 0-40 amp ammeter in series between the rectifier regulator red lead and the battery side of the starter solenoid 3Reconnect the engine's battery cables
r:jl 4Following the manufacturer's directions, connect the variable load tester (carbon pile) across the battery terminalsSteven's Instrument Model NoLB-85 and Snap-on Model NoMT540D are examples of testers available