1993 Johnson Evinrude "ET" 60 thru 70 Service Manual, P/N 508284, Page 334Get this manual

1993 Johnson Evinrude "ET" 60 thru 70 Service Manual, P/N 508284, Page 334

1 Relay Ohmmeter Tests
Throughout this section two symbols are used to interpret electrical troubleshooting resultsUse continuity light or ohmmeter calibrated on low ohms scale to test continuity
[!] This symbol indicates continuity or very low resistancef21 This symbol indicates no continuity or very high resistance To avoid damaging components or troubleshooting equipment, disconnect the battery cables and remove the relays before proceeding1Use continuity light or ohmmeter calibrated on low ohms scale to test continuity2Connect meter leads to relay terminals 87a and 30 The meter must show continuity3Connect meter leads to relay terminals 87 and 30 The meter must show no continuity1sl 4Calibrate an ohmmeter on low ohms scale and connect the leads to relay terminals 85 and 86 The meter must show 70100 ohms1sl 5Connect meter leads to relay terminals 87 and 30Connect 12 volt source to relay terminals 85 and 86 The meter must show continuityrJ1 6Connect meter leads to relay terminals 87a and 30Connect 12 volt source to relay terminals 85 and 86 The meter must show no continuity7Replace relay if your test results vary