1993 Johnson Evinrude "ET" 60 thru 70 Service Manual, P/N 508284, Page 246Get this manual

1993 Johnson Evinrude "ET" 60 thru 70 Service Manual, P/N 508284, Page 246

Stator Resistance CheckAll Models

Disconnect battery cables before proceeding with this check
f31 1Disconnect stator yellow and yellowgray leads from terminal boardf31 2Calibrate ohmmeter on appropriate scaleConnect one ohmmeter lead to stator yellow lead and the other ohmmeter lead to stator yellowgray lead Refer to chart below for the correct value for your engine and stator combination Repair or replace stator if reading is not correct3To check for grounded condition, disconnect both ohmmeter leadsCalibrate ohmmeter on appropriate scaleConnect one ohmmeter lead to clean engine ground and the other ohmmeter lead alternately to both stator leads Ohmmeter should show high reading If ohmmeter shows low reading, stator is grounded and should be repaired or replacedAfter replacing the stator and charge coil assembly, verify correct maximum spark advance using the procedure outlined in Section 1DR4132