13 DR4740

STEPSENSOR COIL TESTQUIKSTART MODELS
Ground Test

[!!] 1Disconnect the 5-pin Amphenol connector between the timer base and power pack

2Set peak-reading voltmeter to "POS" and "5", "SEN" and "5" on Stevens CD-77 meter3Alternately, connect voltmeter between each timer base terminal and clean engine groundCrank engine and observe meter at each connection Any reading indicates sensor coils or leads are grounded Locate and repair ground, or replace timer base4If no reading is indicated in Step 3, go to Output Test
Output Test