High Voltage
not show up with test light or an ohmmeterThis condition may be found by using condenser tester (leakage test) where voltage of approximately 500 volts is applied to the key switch terminalsWith all leads disconnected and the key switch in the OFF position, connect the black lead of the tester to one of the "M" terminals of the key switch1Attach the red lead of the tester to the "8" terminal and apply leakage test2Repeat test by moving the red lead to each of the terminals and applying the leakage testThe meter will indicate if leakage is present3When applying test to other "M" terminalturn key to the ON position 824006

l!J some leakage) to the other terminals in the key switch, but will

["';l In some conditions, the key switch may be shorting (allowing