Flywheel Servicing In order to produce the voltage necessary to run an ignition system, the flywheel magnets must be of particular strengthWeak flywheel magnets can cause low ignition voltage which would affect engine performanceWeak flywheel magnets can also cause low readings on ignition test equipment such as the peak-reading voltmeter, which might cause unnecessary replacement of ignition componentsAn accurate test of alternator output can help determine the flywheel's conditionRefer to Running Test, Alternator Output, Section 7Removal

i all spark leads
'" 1To avoid accidental starting of engine, twist and remove rectifierregulator