1993 Johnson Evinrude "ET" 40 thru 55 Service Manual, P/N 508283, Page 311Get this manual
Prewired Surface Mount Remote Control Servicing Disassembly
ill systemsFailure to do so could result in injury from ignition
sources (sparks) or from contact with moving parts if accidental cranking or starting occurs
1Disconnect battery cables before servicing electrical
1sl 2Remove control handleloosen hex head screw three complete turns
19l 3Support control on blocks to allow the control handle to be
t=J driven off the contro
Place center punch in head of hex head screw, and tap with plastic hammer to disengage the control handle splines from the hub splinesRemove the hex head screw and the control handle