1992 Johnson Evinrude "EN" Electric Outboards Service Manual, P/N 508140, Page 36Get this manual

1992 Johnson Evinrude "EN" Electric Outboards Service Manual, P/N 508140, Page 36

4Use continuity light or ohmmeter calibrated on high ohms scale to test continuity 1221 5With the switch "OFF", the meter must show no continuity
between white lead and terminals through 4At no time should the meter show continuity between any terminal and the switch's metal case6Turn the switch shaft counterclockwise to select speeds through (1 through on 12V models)9851

With the switch on speed 1, the meter must show continuity between white lead and terminal The meter must show no continuity between white lead and terminals 1, 2, 47Turn the switch to speed The meter must show continuity between white lead and terminal The meter must show no continuity between white lead and terminals 1, 2,38Turn the switch to speed The meter must show continuity between white lead and terminal The meter must show no continuity between white lead and terminals 1, 3, 49Turn the switch to speed 4, 12V models The meter must show continuity between white lead and terminal The meter must show no continuity between white lead and terminals 2, 3, 49851