2 Electrical Cable "'" Disconnect battery cables from battery before servicing

i electrical systemsFailure to do so could result in injury
from electrical sparks or from contact with moving parts if accidental cranking or starting occursProvide sufficient slack at motor end to permit steering and tilting of motor without bindingf1l Apply OMC Triple-Guard grease to shaded area shown in figure
[!] 2Align arrows and push connectors firmly together[3] 3Secure the connectors with retainer 4Secure engine cable in J-clamp on lower engine cover

with rubber boot
ill solenoidSecure cable to starter solenoidCover terminal

5Route the positive (red) battery cable to starter

i head ground terminal
"'" 6Secure the negative (black) battery cable to power-

1sl 7Manual Tilt ModelsInstall battery cables, electrical cable and VRO Low Oil Warning wire in grommet Install clamp and secure with two screwsf61 8TrimTilt ModelsBundle the electrical cable, the trimtilt cable, battery cables and the VRO Low Oil Warning wire, and wrap the cables using the piece of rubber wrap supplied with the battery cables Install tie strap around rubber wrap Twist tie strap around so the connection is facing down to fit in lower engine cover Tighten and cut tie strap Place rubber wrap in opening in front of lower engine coverInstall clamp and secure with two screws