1992 Johnson Evinrude "EN" 90 deg. Cross V Service Manual, P/N 508145, Page 124Get this manual

1992 Johnson Evinrude "EN" 90 deg. Cross V Service Manual, P/N 508145, Page 124

12 DR4079

Ohmmeter Test

INote All ohmmeter tests must be performed with the engine not running1Calibrate ohmmeter on appropriate scale2Attach ohmmeter black lead to timer base connector, terminalE" r:J2l 3Alternately, attach ohmmeter red lead to each terminal in the timer base connectorObserve ohmmeter reading at each connection Meter must show 40 10 ohmsf131 4To test for grounded condition, connect ohmmeter, alternately, between each timer base terminal location and clean engine ground Meter must show high reading If meter shows low readinglocate and repair ground or replace timer base5Complete all circuits disconnected during this test