Control Handle Positions When the control handle is in NEUTRAL: the neutral lockout slider must engage the index plate notch securely the neutral lockout knob must be down the fast idle lever must be free to move to the START position When the control handle is in FORWARD: the neutral lockout knob must be up the lockout slider must not engage the index plate notch the fast idle lever must be locked in the RUN position As you move the control handle into NEUTRAL: the neutral lockout knob must snap down the lockout slider must engage the index plate notch the fast idle lever must be free to move into the START position When the control handle is in REVERSE: the neutral lockout knob must be up the lockout slider must not engage the index plate notch the fast idle lever must be locked in the RUN position If your test results vary, check the true NEUTRAL position of the control handle and index plateRefer to Assembly, Page 9-14Neutral Start Switch 1Verify that the control handle is in true NEUTRAL positionRefer to Control Handle Positions2Use an ohmmeter calibrated on appropriate scale or continuity light to test continuity 0 3Connect meter as shown0 4Turn the key to the START position Meter must show continuityf81 5Move control handle to FORWARD position, and turn key to the START position Meter must show no continuityf81 6Move control handle to REVERSE position, and turn key to the START position Meter must show no continuity7If your test results vary, test neutral start switch and wiringC02072