1992 Johnson Evinrude "EN" 9.9 thru 30 Service Manual, P/N 508142, Page 296Get this manual

1992 Johnson Evinrude "EN" 9.9 thru 30 Service Manual, P/N 508142, Page 296

Starter Circuit Check Chart, 2030 Remote INotel Battery must be fully charged

Procedure Remove black lead from ground at G) Connect voltmeter between G) and common engine groundTurn key to START positionVoltmeter should show battery voltageConnect meter at Turn key to START position
Result aIf no reading, go to Step

Check voltage between ground and G)Steps thru Remove starter to solenoid cable from (j) to prevent starter engagement while making checksbetween ground

bIf meter reads battery voltage, reconnect black lead to ground and go to Step

II Check voltage liiI and
aIf meter reads battery voltage, lead is open between CD and

INotel Steps thru Turn key OFF before connecting and disconnecting meterTurn key to START position after connecting

bIf no reading, go to Step