1992 Johnson Evinrude "EN" 9.9 thru 30 Service Manual, P/N 508142, Page 138Get this manual

1992 Johnson Evinrude "EN" 9.9 thru 30 Service Manual, P/N 508142, Page 138

9 DR4188

Ohmmeter Test INotel All ohmmeter tests must be performed with the engine NOT running1Insert jumper wires in armature plate connector, terminals "A" and "D"2Calibrate ohmmeter on appropriate scaleConnect between jumpers Meter must show 575 60 ohmsr,Ql 3To test .for grounded condition, connect ohmmeter alternately between each jumper and clean engine ground Any needle movement indicates charge coil or leads are grounded Locate and repair ground, or replace charge coil4Complete all circuits disconnected during this test