1992 Johnson Evinrude "EN" 60 thru 70 Service Manual, P/N 508144, Page 117Get this manual

1992 Johnson Evinrude "EN" 60 thru 70 Service Manual, P/N 508144, Page 117

IGNITION OUTPUT TESTS ill plugs installed and torqued in the cylinder headIf necessary to remove the spark plugs, be sure to keep the spark tester away from open spark plug holesThe following series of steps will systematically isolate problem area in the ignition systemTo reduce your troubleshooting time and to avoid incomplete results, perform these steps in the order written
I:A All cranking output tests must be performed with spark

STEPTOTAL OUTPUT TEST

[!] 1Twist and remove the spark plug leads from all spark plugsf21 2Adjust the gap on the spark tester to V2 in(12 mm)Connect t=I tester leads to the spark plug leadsSecure tester clip to clean engine ground'r

To prevent possible arcing of high voltage, route tester leads at least in(51 mm) from any metal surfaceTo avoid possible shock hazard, do not handle ignition coils