35 Amp Stator
50 40 30 20 10
1000 2000 3000 4000 5000 6000
Running Test, Alternator Output
Disconnect battery cables before proceeding with this check
1Remove the rectifierregulator red lead from the battery side of the starter solenoid2Wire 0-40 amp ammeter in series with the rectifierregulator red lead and the wiring harness red lead
i coming in contact with engine ground while the engine is
runningContact could cause arcing