1992 Johnson Evinrude "EN" 60 deg Loop V Service Manual, P/N 508146, Page 235Get this manual

1992 Johnson Evinrude "EN" 60 deg Loop V Service Manual, P/N 508146, Page 235

High Voltage
L!J some leakage) to the other terminals in the key switch, but will

[";l In some conditions, the key switch may be shorting (allowing not show up with test light or an ohmmeterThis condition may be found by using condenser tester (leakage test) where voltage of approximately 500 volts is applied to the key switch terminals824006

With all leads disconnected and the key switch in the OFF position, connect the black lead of the tester to one of the "M" terminals of the key switch1Attach the red lead of the tester to the "8" terminal and apply leakage test2Repeat test by moving the red lead to each of the terminals and applying the leakage testThe meter will indicate if leakage is present3When applying test to other "M" terminal, turn key to the ON position