1992 Johnson Evinrude "EN" 60 deg Loop V Service Manual, P/N 508146, Page 182Get this manual

1992 Johnson Evinrude "EN" 60 deg Loop V Service Manual, P/N 508146, Page 182

1sl 6Use OMC Seal Installer, PIN 336311, to install two new seals back to back in the rear of the bearing housingApply OMC Gasket Sealing Compound to the metal casings of the seals before installingInstall the inner seal with lip facing toward the bearing housing, then the outer seal with lip facing away from the bearing housingApply OMC Triple-Guard grease to the seal lips after installing rJl 7Lightly apply OMC Triple -Guard grease to new bearing housing a-ringInstall the a-ring in its groove in the housingDriveshaft Bearing Housing Service The driveshaft bearing is not serviceableReplace the bearing housing if the bearing is worn or damagedAlso, inspect the driveshaft bearing surface if the bearing is damagedf81 1Remove the two driveshaft bearing housing seals using OMC Puller Bridge, PIN 432127, and OMC Large Puller Jaws, PI 432129Discard the seals2Remove the a-ring from the bearing housing and discard3Clean the bearing housing in solvent to remove sealer from the seal bore and the a-ring groove1s1 4Install new seals back to back in the bearing housing using OMC Seal Installer, PIN 330268Apply OMC Gasket Sealing Compound to the metal casings of the seals before installingInstall the inner seal with flush lip facing toward the bearing housing, then the outer seal with extended lip facing away from the bearing housingApply OMC Triple-Guard grease to the seal lips after installing 191 5