1992 Johnson Evinrude "EN" 60 deg Loop V Service Manual, P/N 508146, Page 118Get this manual

1992 Johnson Evinrude "EN" 60 deg Loop V Service Manual, P/N 508146, Page 118


STEPCHARGE COIL TEST

Ground Test 1Disconnect 6-pin Packard connector between stator and power pack2Attach 6-pin Packard test adapter from OMC Ignition Test Kit, PI 434017, to stator connector3Set peak-reading voltmeter to "POS" and "500" 1.jl 4Alternately connect meter between brown, brownyellow stator leads, and clean engine groundCrank engine and observe meter at each connectionAny reading indicates charge coil is grounded Locate and repair ground, or replace stator assembly5Repeat Step using brownblack and brownwhite stator leads6If no reading is indicated in Steps or 5, go to Output TestOutput Test 1Set peak-reading voltmeter to "POS" and" 500"2Attach meter black lead to brown stator leadAttach meter red lead to the brownyellow stator 3Crank engine and observe meter4Repeat Steps and with meter black lead attached to brownblack stator lead and meter red lead attached to brownwhite stator lead: If meter shows 150 volts or higher, go to next step indicated in Troubleshooting Sequence Chart, Page 3-24 If meter shows less than 150 volts, check condition of wiring and connectors If wiring and connector condition is good, go to Ohmmeter TestOhmmeter Test INotel All ohmmeter tests must be performed with engine NOT running1Calibrate ohmmeter on appropriate scale