Ohmmeter TestKey Switch
INotel All ohmmeter tests must be performed with the engine NOT running1Separate the 5-pin Packard connector between the power pack and key switch2Attach the 5-pin Packard test adapter from OMC Ignition Test Kit, PI 434017, to the engine harness connector3Install the emergency stop switch clip12l 4Calibrate ohmmeter on appropriate scale and connect one meter lead to clean engine ground and the other meter lead to one of the two blackyellow leads: Key OFF, meter must show low reading Key ON, meter must show high reading5Repeat Step using remaining blackyellow lead
IN tel If the ohmmeter test on both leads are good, the power pack blocking diode is shortedReplace