Power Supply Tests 1Disconnect battery cables from batteryf1l 2Disconnect yellowblue, yellowgray, and yellow power supply leads from the terminal boardf21 3Disconnect the yellowred power supply lead from the starter solenoid
] 4Disconnect the warning horn 3-pin Amphenol connectorr:;l 5Calibrate ohmmeter on appropriate scaleConnect meter black lead to terminal "8" (purple lead of engine's warning horn connector)
1sl 6Connect meter red lead to power supply yellowred lead
EJ Note meter readingReverse the ohmmeter connections, or