1992 Johnson Evinrude "EN" 40 thru 55 Service Manual, P/N 508143, Page 271Get this manual

1992 Johnson Evinrude "EN" 40 thru 55 Service Manual, P/N 508143, Page 271

3Capacity Test Satisfactory capacity tests can be made only when the battery electrolyte equals or exceeds 1.225 specific gravity at 80 (2JO C) [3] 4Terminal Voltage Test
ill procedures
Use extreme caution during any load testingImproper could overheat battery and cause electrolyte gassingThis might cause an explosive atmosphereaVariable Load High Rate Discharge Tester (Recommended) Connect tester to battery terminal postsDischarge at rate of three times battery ampere hour rating for 15 secondsIf the voltage is 9.6 volts or higher at the end of 15 seconds, the battery has good output capacitybFixed Resistance Tester This equipment has built-in load for high-rate discharge testingFollow equipment manufacturer's instructions regarding test period and meter readingscEngine Load for Resistance Twist and remove the spark plug leadsConnect voltmeter across the batteryCrank engine for 15 secondsIf voltage is 9.6 volts or higher at the end of 15 seconds, the battery has good output capacity12009