14 D1I4188 DR4187

Ohmmeter Test INotel All ohmmeter tests must be performed with the engine NOT running1Calibrate ohmmeter on appropriate scale2Insert jumper wires in armature plate connector, terminals "8" and "C"3Calibrate ohmmeter on appropriate scaleConnect between jumpers Meter must show 40 10 ohms[14[ 4To test .for grounded condition, connect ohmmeter alternately between each jumper and clean engine ground Any needle movement indicates sensor coil or leads are grounded Locate and repair ground, or replace sensor coil5Complete all circuits disconnected during this test